High Accuracy
Reaching new heights
Built in Camera and Printer
Making a difference every day
Reporting the Measurement Result
Save to Device Memory
Transfer of Data to Computer
Building connections
General Specification
High Accuracy and Reliability: The NAM-E30 ensures precise and reliable operation by recording measurement results in its memory along with the device's serial number and real-time data.
Easy and Ergonomic Operation: The NAM-E30C delivers a practical and user-friendly experience with its color touchscreen display, shock-resistant structure, and built-in printer.
Automatic ID Entry: The QR code and barcode reader allow fast and accurate recording of credentials in the device’s memory.
GPS-Based Measurement Location Tracking: The device enhances the reporting process by recording the location where measurements are taken.
Wireless Communication Features: The product transfers data from a long distance with wireless connection options such as GPRS-GSM/Wi-Fi/Bluetooth.
Integrated Thermal Printer: The built-in thermal printer allows for instant printing of measurement results.
Versatile Measurement Modes NAM-E30C features a variety of measurement modes that accommodate different user requirements:
Automatic Mode: A standard measurement option for individuals who provide an adequate breath sample.
Manual and Passive Modes: Alternative measurement options for individuals who are unable to give enough breath samples or unconscious people The passive mode is also used to measure ambient alcohol levels.
Refuse Mode: The feature to register individuals who refuse to take a measurement.
Technological Advantages
Fast and Reliable Reporting: Document measurement results instantly thanks to the device's integrated thermal printer.
Secure Data Transfer: Transfer and manage up to 100,000 records securely with the NAM-DATAPro software.
Portable and Durable Design: The ergonomic design, wrist strap, strap belt, silicone cover, and sunlight-readable screen ensure dependable performance in all conditions.
Wide Usage Areas The NAM-E30 can be used in a wide range of applications, from traffic controls to workplace inspections, enhancing safety with its precise measurement capabilities and fully meeting professional needs.
Experience
the real
innovation
Every groundbreaking innovation, whether meticulously engineered or born from spontaneous creativity, contains stories waiting to be discovered.
Technical Details
- Sensor: Electrochemical Fuel Cell
- Mouthpiece: Disposable (hygienically produced and packaged), passive cup
- Measurement Mode: Automatic /Manual/Passive/Refuse
- Measuring Range: 0.00-6.00‰ (promille)
- Start-up Time: Less than 6 sec.
- Response Time: Up to 15 seconds (immediately at zero ‰)
- Recovery Time: In the range of 0.50-2.00‰ no more than 30 sec.
- Operating Temperature: -10C to (±) 50C
- Storage Temperature: -20C to (±) 60C
- Pressure: 600-1400 hPa
- Humidity: 20-98 % r.h
- Minimum Breathing Volume: 1.2 L (adjustable)
- Blowing Time: No more than 6 seconds.
- Sampling: Self-operating electronic pump
- Measurement Unit: Promille (w/v) standard, (adjustable to all units used in the world).
- Data Entry: Three-key operation and touchscreen keyboard
- Auto Shutdown Time: Adjustable
- Energy Saving Mode: Settable, a) Short-term b) Automatic dimming of screen brightness in idle mode c) Standby mode. The modules (such as the camera and QR/barcode reader) can also be disabled when not used.
- Display: 3.5-inch touch TFT Screen
- Memory: Standard 7500 (may vary depending on the data to be entered)
- Calibration: Every 6 months
- Calibration Method: Dry gas and/or bath
- Battery: Rechargeable, 7.4V Lithium-ion battery (Optional Alkaline and Ni-Mh Battery)
- Wireless (Optional): GSM, Bluetooth, Wi-Fi
- Location (Optional): GPS
- Charging Adapter: Mains (220/110V AC) and/or cigarette plug of vehicle (12/24V DC)
- Data Entries: These are saved by the device during measurement and displayed in the printer report.
- Standart: Officer's full name, registration number, driver's full name, and identification number.
- Optional: license plate, two different pieces of information as per request, for example; gender, province code, etc.
- Record Transfer: The records from the device are transferred to a computer using the NAM-DATAPro software (optional).
- Barcode/QR Code: Optional, (for reading identification information)
- Knob, Joystick: Optional, Control of all functions
Standards:
- DOT/NHTSA Evidential Class compliance
- EN15964 EU
- CE certification (EMC, LVD)
- EN60068-2-6 Vibration
- EN60068-2-64 Vibration
- EN60068-2-27 Shock

Versatile Application
The NAM-C20 provides an effective solution across industries where occupational safety is paramount.

Driver Checkpoints and Hotels: A cost-effective and reliable breath alcohol measurements.

Factories and Stadiums: Hygienic, non-contact measurements in areas with large gatherings.

Law enforcement: Ideal for preliminary alcohol testing by security forces.

Mining and Construction Sites: Fast and precise measurements to ensure worker safety.